HPN12XHM Haier Room Air Conditioner Built In Replacement Parts
Parts List
Category | Part Number | Description | Demand | Availability |
---|---|---|---|---|
AC-0200-36 | Haier Bar Schematic Location: 43 | No | ||
Base | WJ76X24143 | GE Base Pan Schematic Location: 1 | Ships in 90 days 19.91 | |
Cushion | AC-0344-13 | Haier Bearing Schematic Location: 34 | No | |
Blade | WJ73X24144 | GE Blade - Swing Motor Schematic Location: 6 | In Stock In stock 3.66 | |
Axle, Roller, Shaft Wheel | WJ88X22300 | GE Blower-wheel Schematic Location: 26 | Y | In Stock In stock 13.49 |
Bracket, Flange, Blade | AC-0850-158 | Haier Bracket-switch Schematic Location: 18 | No | |
Cover,Cap | WJ01X24007 | GE Cap - Window Panel Schematic Location: 72 | Y | In Stock In stock 6.05 |
Pipe, Tube, Hose, Fitting | AC-7750-32 | Haier Capilary Tube Schematic Location: 21 | No | |
AC-1405-36 | Haier Capillary Schematic Location: 21 | No | ||
Foam | AC-1450-163 | Haier Carton-cardboard Schematic Location: 67 | No | |
AC-1450-158 | Haier Carton-packaging Schematic Location: 61 | No | ||
AC-1450-159 | Haier Carton-packaging Schematic Location: 66 | No | ||
Case | AC-1470-60 | Haier Case-fan Schematic Location: 27 | No | |
Holder | AC-3500-170 | Haier Casing - Fan Schematic Location: 36 | No | |
AC-1480-20 | Haier Casing-fan Schematic Location: 22 | No | ||
AC-1480-59 | Haier Casing-fan Schematic Location: 31 | No | ||
Leg, Foot, Caster | WJ01X22325 | GE Caster Schematic Location: 2 | Y | In Stock In stock 3.41 |
Compressor - Sealed System | AC-1750-215 | Haier Compressor Schematic Location: 11 | No | |
Condensor | AC-1800-204 | Haier Condenser Schematic Location: 20 | No | |
Connector | WJ76X24001 | GE Connector-exhaust Hose Schematic Location: 70 | Y | No |
AC-1900-60 | Haier Cord - Power Schematic Location: 35 | No | ||
Cover,Cap | AC-1950-351 | Haier Cover Schematic Location: 37 | No | |
Cover,Cap | AC-1950-340 | Haier Cover Schematic Location: 60 | No | |
Cover,Cap | AC-1950-473 | Haier Cover Schematic Location: 66 | No | |
Cover,Cap | WJ86X23647 | GE Cover Schematic Location: 74 | No | |
Cover,Cap | AC-1950-233 | Haier Cover-drain Bucket Schematic Location: 7 | No | |
Deflector & Chute | AC-2100-30 | Haier Deflector-air Schematic Location: 45 | No | |
Plate | WJ71X23749 | GE Discharge Grille Schematic Location: 70 | Y | In Stock In stock 13.61 |
Plug | WJ01X23783 | GE Drain Plug Schematic Location: 64 | Y | In Stock In stock 6.18 |
Evaporator | AC-2650-137 | Haier Evaporator-assembly Schematic Location: 30 | No | |
Housing | WJ76X24142 | GE Fan Casing Schematic Location: 22 | In Stock In stock 6.05 | |
WJ71X22295 | GE Fan-cross Flow Schematic Location: 32 | Y | In Stock In stock 25.08 | |
Filter | WJ71X22334 | GE Filter-air Schematic Location: 57 | Y | In Stock In stock 7.19 |
Exhaust | WJ71X24006 | GE Fixture Schematic Location: 28 | No | |
Plate | AC-5310-17 | Haier Fixture Schematic Location: 63 | No | |
Float | AC-2855-02 | Haier Float Schematic Location: 9 | No | |
AC-2868-09 | Haier Foam-packaging Schematic Location: 65 | No | ||
AC-3150-120 | Haier Grill Schematic Location: 28 | No | ||
Housing | WJ71X23748 | GE Grill-fan Housing Schematic Location: 71 | Y | In Stock In stock 6.69 |
WJ71X23997 | GE Grill-intake Schematic Location: 58 | Y | In Stock In stock 5.55 | |
Compressor - Sealed System | AC-3200-12 | Haier Grommet-compressor Schematic Location: 12 | No | |
Coupling | WJ01X23646 | GE Heat Exhaust Hose Connector Schematic Location: 69 | No | |
Holder | AC-3500-171 | Haier Holder Schematic Location: 46 | No | |
Holder | AC-3500-172 | Haier Holder Schematic Location: 47 | No | |
Holder | AC-3500-167 | Haier Holder Schematic Location: 59 | No | |
Holder | AC-3500-173 | Haier Holder-board Schematic Location: 38 | No | |
Holder | AC-3500-164 | Haier Holder-pcb Schematic Location: 55 | No | |
WJ35X23750 | Haier Hose-exhaust Schematic Location: 2222 | No | ||
Pipe, Tube, Hose, Fitting | WJ35X23750 | GE Hose-exhaust Schematic Location: 69 | Y | In Stock In stock 87.08 |
Keypad | AC-3899-05 | Haier Keypad Schematic Location: 50 | No | |
Tank | AC-4250-203 | Haier Lid-tank Schematic Location: 8 | No | |
Louver | AC-4440-66 | Haier Louver Schematic Location: 44 | No | |
Switch | WJ27X22317 | GE Micro Switch Schematic Location: 10 | Y | In Stock In stock 6.44 |
Motor,Ice Maker Motor | AC-4550-310 | Haier Motor Schematic Location: 5 | No | |
Pump, Motor | WJ88X22344 | GE Motor - Exhaust Schematic Location: 23 | Y | No |
Pump, Motor | WJ98X24146 | GE Motor-fan (Ls-16t3-02) Schematic Location: 33 | Ships in 90 days 58.09 | |
WJ26X22318 | GE P.c.b. Schematic Location: 53 | In Stock In stock 58.93 | ||
Control | AC-5210-139 | Haier P.c.b.-control Schematic Location: 39 | No | |
AC-5210-140 | Haier P.c.b.-display Schematic Location: 54 | No | ||
Base | AC-5150-80 | Haier Pan-base Schematic Location: 1 | No | |
Panel | AC-5200-457 | Haier Panel-front Schematic Location: 48 | No | |
Panel | AC-5200-458 | Haier Panel-rear Schematic Location: 56 | No | |
Connector | AC-5255-496 | Haier Pipe-connector Schematic Location: 16 | No | |
Pipe, Tube, Hose, Fitting | AC-5255-495 | Haier Pipe-suction Schematic Location: 13 | No | |
Plate | AC-5300-347 | Haier Plate Schematic Location: 29 | No | |
Plate | AC-5300-621 | Haier Plate Schematic Location: 29 | No | |
Plate | WJ65X23752 | GE Plate ( 252.5Mm ) Schematic Location: 73 | In Stock In stock 6.55 | |
Plate | WJ65X23782 | GE Plate ( 505Mm ) Schematic Location: 71 | Y | In Stock In stock 38.19 |
Plate | WJ65X23757 | GE Plate ( 505Mm ) Schematic Location: 72 | In Stock In stock 12.74 | |
Plate | WJ65X23753 | GE Plate - Half Width Schematic Location: 75 | Y | In Stock In stock 27.00 |
Plate | WJ65X23664 | GE Plate W/hole Schematic Location: 73 | No | |
Panel | AC-5300-355 | Haier Plate-front Panel Schematic Location: 49 | No | |
Plate | WJ65X23751 | GE Plate-solid Schematic Location: 74 | Y | In Stock In stock 28.35 |
Plate | AC-5300-171 | Haier Plate-strike Schematic Location: 4 | No | |
Plug | WJ01X24015 | GE Plug-drain Schematic Location: 3 | Y | In Stock In stock 3.41 |
Power Supply | A7302-370 | Haier Power Supply Cord Complete Schematic Location: 36 | No | |
Remote Control | WJ26X23991 | GE Remote Schematic Location: 68 | In Stock In stock 31.89 | |
Bag | WJ01X23760 | GE Screw-complete Bag Schematic Location: 75.1 | Y | In Stock In stock 7.05 |
Sensor, Thermistor, Thermostat | WJ26X22322 | GE Sensor For Room Temperature Schematic Location: 62 | Y | In Stock In stock 6.05 |
Plug | WJ01X22288 | GE Soft Cap Schematic Location: 3 | Y | In Stock In stock 3.41 |
Plug | WJ01X22289 | GE Soft Cap Schematic Location: 65 | Y | No |
A5806-130 | Haier Strike Schematic Location: 40 | No | ||
AC-6955-10 | Haier Striker Schematic Location: 51 | No | ||
AC-6955-11 | Haier Striker Schematic Location: 52 | No | ||
Foam | AC-6998-31 | Haier Styrofoam-packaging Schematic Location: 62 | No | |
Foam | AC-6998-29 | Haier Styrofoam-packaging Schematic Location: 63 | No | |
Foam | AC-6998-30 | Haier Styrofoam-packaging Schematic Location: 64 | No | |
Switch | AC-7100-07 | Haier Switch-micro Schematic Location: 10 | No | |
Pipe, Tube, Hose, Fitting | AC-7750-222 | Haier Tube-connecting Schematic Location: 15 | No | |
Pipe, Tube, Hose, Fitting | AC-7750-224 | Haier Tube-suction Schematic Location: 14 | No | |
Valve, Float Assembly | AC-7800-96 | Haier Valve-4 Way Revesring Assy Schematic Location: 17 | No | |
Vent | AC-7900-15 | Haier Vent-discharge Schematic Location: 42 | No |